Liebert GXT5 1ph UPS 3kVA input plug IEC - Vertiv
| Battery Information |
| Battery Life |
5 Year |
| Battery Chemistry |
Lead Acid |
| Hot Swappable |
Yes |
| Battery Size |
12V |
| Battery Capacity |
9000 mAh |
| Hot Pluggable |
Yes |
| Number of Batteries |
6 |
| Backup/Run Time (Half Load) |
10.80 Minute |
| Backup/Run Time (Full Load) |
3.30 Minute |
| Battery Characteristics |
Valve-regulated, Non-spillable |
| Replaceable Battery |
Yes |
| DC System Voltage |
72 V DC |
| Typical Battery Recharge Time |
3 Hour |
| Controls/Indicators |
| Status Indicators |
Colored Graphic LCD Display: - UPS status
- UPS configuration
|
| Environmental Conditions |
| Sound Emission |
48 dB |
| Maximum Operating Temperature |
40°C |
| Maximum Operating Elevation |
3 km |
| Interfaces/Ports |
| VGA |
No |
| Network (RJ-45) |
Yes |
| Modem (RJ-11) |
No |
| Serial Port |
Yes |
| USB (HID Compliant) Port |
Yes |
| Management |
| Network Management |
SNMP/HTTP Remote Monitoring |
| Miscellaneous |
| TAA Compliant |
No |
| Energy Star |
Yes |
| Physical Characteristics |
| Weight (Approximate) |
28.50 kg |
| Form Factor |
Rack/Tower |
| Rack Height |
2U |
| Height |
85 mm |
| Width |
430 mm |
| Depth |
540 mm |
| Product Color |
Black |
| Color Family |
Black |
| Power Description |
| Circuit Breaker |
Yes |
| Input Voltage |
230 V AC |
| Output Voltage |
240 V AC |
| Output Voltage |
230 V AC |
| Output Voltage |
220 V AC |
| Output Voltage |
208 V AC |
| Output Voltage |
200 V AC |
| Waveform Type |
Pure Sine Wave |
| Input Voltage Range |
115 V AC - 288 V AC |
| Input Frequency |
70 Hz |
| Load Capacity (VA) |
3 kVA |
| Load Capacity (Watt) |
3 kW |
| Technical Information |
| Application/Usage |
Network Closet |
| Application/Usage |
Network Workstation |
| Application/Usage |
Server |
| Application/Usage |
VoIP |
| Application/Usage |
Edge Computing |
| Application/Usage |
Large Network Peripheral |
| Application/Usage |
Mission Critical Equipment |
| Protection Type |
Output Over Voltage |
| Protection Type |
Electric Shock |
| Protection Type |
Over Charge |
| Protection Type |
Over Current |
| Protection Type |
Over Loading |
| Protection Type |
Over Power |
| Protection Type |
Over Temperature |
| Protection Type |
Over Voltage |
| Protection Type |
Power Failure |
| Protection Type |
Quad |
| Protection Type |
Harmonics |
| Protection Type |
High/Low Voltage |
| Protection Type |
Inrush Current |
| Protection Type |
Lightning |
| Protection Type |
Line Noise |
| Protection Type |
Low Battery |
| Protection Type |
No Load |
| Protection Type |
Noise |
| Protection Type |
Output Over Current |
| Protection Type |
Surge |
| Protection Type |
Temperature |
| Protection Type |
Thermal Overload |
| Protection Type |
Electronic Current Limit |
| Protection Type |
EMI |
| Protection Type |
EMI / RFI |
| Protection Type |
Excessive Low Battery |
| Protection Type |
Fuse |
| Protection Type |
RFI |
| Protection Type |
Sag |
| Protection Type |
Short Circuit |
| Protection Type |
Soft Start |
| Protection Type |
Spike |
| Protection Type |
Transient |
| Protection Type |
Under Current |
| Protection Type |
Under Voltage |
| Protection Type |
Output Short Circuit |
| Protection Type |
Discharge |
| Protection Type |
Deep Discharge |
| Protection Type |
Dataline Surge |
| Protection Type |
Brownout |
| Protection Type |
Black Out |
| Protection Type |
AC Surge |
| Protection Type |
AC Noise |
| Cord Length |
3.05 m |
| Phase |
Single Phase |
| Receptacle Type |
IEC 60320 C19 |
| Receptacle Type |
IEC 60320 C13 |
| EMI/RFI Noise Filter |
Yes |
| Transfer Time |
0 ns |
| Receptacle Detail |
6 x IEC 60320 C13 |
| Receptacle Detail |
1 x IEC 60320 C19 |